Control Cable Factory Suppliers Manufacturers Quotes

Control Cable

Control Cable

Control Cable

Standard

The control cable can be produced according to the standard GB9330-1988,and the factory can also manufacture the cables in accordance with other standards.

 QQ图片20170830152253.jpg

Scope of Application

The control cable are suitable for the wiring of electrical controlling equipments and instrument, monitoring and controlling return circuit, electrical protection and measurement in power distribution unit under the circumstance that the rated voltage is up to 450/750V AC.

The long-time working temperature of conductor of PVC insulated cable is 70°C

The long-time working temperature of conductor of XLPE insulated cable is 90°C

The temperature for laying the cables can not be lower than 0.Permissible bending radius(r):unarmored cable: r6D;(D: outer diameter of the cable);armored or copper-tape screened cable: r12D;shielded flexible cable: r6D

 

Type& Specification

Type

Name

Section Area(mm²)

No. of Cores

Application Site

KVV

Copper Conductor, PVC Insulated and Sheathed Control Cable

0.75,1.0,1.5 2.5

2-16

Permanent installation indoors, in cable ditches or pipes

4,6

2-14

10

2-10

KVVP

Copper Conductor, PVC Insulated and Sheathed, Braiding Shielded  Control Cable

0.75,1.0,1.5,2.5

2-61

Permanent installation indoors, in cable ditches or pipes where shielding is required

4,6

2-14

10

2-10

KVVP2

Copper Conductor, PVC Insulated and Sheathed, Copper-tape Screened Control Cable

0.75,1.0,1.5,2.5

4-10

Permanent installation indoors, in cable ditches or pipes where shielding is required

4,6

7-61

10

4-10

KVV22

Copper Conductor, PVC Insulated and Sheathed, Steel tape Armored Control Cable

0.75,1.0,1.5,2.5

7-61

Permanent installation indoors, in cable ditches, Be able to withstand stronger external mechanical force

4,6

4-14

10

4-14

KVVR

Copper Conductor, PVC Insulated and Sheathed, Flexible Control Cable

0.5,1.0,1.5,2.5

4-61

Installation indoors where flexibility and movability are required

KVVRP

Copper Conductor, PVC Insulated and Sheathed, Braiding shielded Flexible Control Cable

0.5,0.75,1.0

4-61

Installation indoors where flexibility shielding and movability are required

1.5,2.5

4-48

KYJV

Copper Conductor, XLPE Insulated and PVC Sheathed Control Cable

0.75,1.0,1.5,2.5

2-16

Permanent installation indoors, in cable ditches or pipes

4,6

2-14

10

2-10

KYJVP

Copper Conductor, XLPE Insulated, Braiding Shielded, PVC Sheathed Control Cable

0.75,1.0,1.5,2.5

2-61

Permanent installation indoors, in cable ditches or pipes where shielding is required

4,6

2-14

10

2-10

KYJV22

Copper Conductor, XLPE Insulated, Steel-tape Armored, PVC Sheathed Control Cable

0.75,1.0,1.5,2.5

7-61

Permanent installation indoors, in cable ditches, pipes or underground Be cable to with stand stronger external mechanical force

4,6

4-14

10

4-10

KYJVP2

Copper Conductor, XLPE Insulated, Copper tape Screened, PVC Sheathed Control Cable

0.75,1.0,1.5,2.5

7-61

Permanent installation indoors, in cable ditches or pipes where shielding is required

4,6

4-14

10

4-10

KYJVR

Copper Conductor, XLPE Insulated, PVC Sheathed Flexible Control Cable

0.5,0.75,1.5,2.5

4-61

Installation indoors where flexibility and movability are required

KYJVRP

Copper Conductor, XLPE Insulated, Braiding Shielded, PVC Sheathed Flexible Control Cable

0.5,0.75,1.0

4-61

Installation indoors where flexibility shielding and movability are required

1.5,2.5

4-48

 


Please feel free to give your inquiry in the form below. We will reply you in 24 hours.
Message